An egress window is a window large enough for a person to climb through in an emergency, and the rules for them are among the most important in a basement finish. A basement bedroom without a compliant escape route can be a serious safety hazard, and building inspectors pay close attention to these openings. Understanding what an egress window must do, and when one is required, helps you plan the layout and the budget before you frame the walls.

The requirements are set by local building codes, which often follow a national model code. The exact numbers can vary from one jurisdiction to another, so the details here describe common requirements and should be confirmed with your building department before you design the window.

What an egress window does

Egress means a way out. In a home, the code requires an emergency escape and rescue opening in every sleeping room, and in a basement that often means a window. The opening must be large enough for an adult to climb through, and it must be reachable without special tools or keys. The purpose is simple: if a fire or other emergency blocks the stairway, occupants need another way to leave and firefighters need a way in.

The requirement applies to rooms used for sleeping. In new construction, the model code requires an escape opening in a basement with habitable space even without a bedroom. When an existing basement is finished, the requirement is usually triggered by a new sleeping room. Ask your building department which rule applies to your project. Some jurisdictions also require egress in other spaces, so check the code for each room in your plan.

Common size and height requirements

The model residential code generally requires a net clear opening of at least 5.7 square feet, reduced to 5.0 square feet for openings at grade-floor level or below grade, which covers most basement windows. Some jurisdictions use an older or amended edition, so confirm the figure with your building department. The window must also have a minimum clear height and width, often around 24 inches high and 20 inches wide, and the sill must sit no higher than about 44 inches above the floor. These numbers are useful for planning, but your local code may differ, so confirm them with the building department.

The net clear opening is the actual space available when the window is open, not the size of the glass or the frame. Sashes, screens and hardware can reduce the opening, so choose a window that is rated for egress and check the net clear opening with the manufacturer's data. A window that looks large enough on paper may fail inspection because the frame cuts into the clear space.

Window wells and access

When the window is below ground level, a window well is usually needed to allow the opening to meet the code and to keep soil from falling against the glass. The well must be large enough to let the window open fully and allow a person to climb out. Model codes commonly require a well with at least 9 square feet of floor area and at least 36 inches of horizontal projection from the wall, in addition to the ladder rule for wells deeper than 44 inches. Confirm the local figures. If the well is deeper than about 44 inches, many codes require a ladder or steps built into the well, and the ladder must not block the window opening.

Keep the well clear of debris and plants, and make sure the cover, if one is installed, can be opened from inside without a key. Some well covers are designed to shed water and debris while still allowing a quick exit. Check the cover design with the inspector before installation.

Adding an egress window to an existing basement

Adding a window to an existing foundation wall is a structural project. The contractor must cut an opening in the concrete or block wall, install a lintel to carry the load above the opening, and waterproof the new window. This work typically requires a permit, and the engineer or inspector may need to review the lintel design. The cost depends on the wall material, the depth of the excavation and the window well design.

Before you commit, check the location on the outside of the house. Confirm that the window well will not block a path, that the soil and drainage will work, and that utilities such as gas lines, electrical service and water lines are not in the way. Call the utility locating service before digging, since the rules for that call are set by state law.

Before you call a contractor

Find out from your building department which rooms need egress and what the local dimensions are. Ask a contractor to measure the wall, check the utility locations and quote the window, the well and the lintel as separate items. Make it a priority to plan the bedroom location around the window, since moving an egress opening later is expensive.