← All articles
Bathroom Remodeling

How to choose a bathroom exhaust fan

Learn how to size a bathroom exhaust fan by room area, place it for good airflow, vent it outdoors and check noise and humidity ratings before you buy one.

A woman holding a white circular exhaust fan in a room under renovation, while a young boy points up towards an open square hole in the ceiling.

A bathroom exhaust fan is one of the least exciting parts of a remodel, and one of the most important. Showers and baths release large amounts of water vapor into the room. If that moisture stays in the air, it condenses on cold surfaces, feeds mold, lifts paint and slowly damages drywall, framing and the finishes you paid to install. A fan that is the right size, placed well and vented outdoors removes that moisture before it causes damage, and it does so without the noise or drafts that drive people to switch it off.

Many fans fail not because the unit is poor but because the installation is wrong. A fan that is too small, placed in the wrong spot or vented into the attic will not do its job. The points below help you size the fan, place it and check the details that matter in daily use.

Size the fan for the room

Fans are rated in cubic feet per minute, or CFM, which describes how much air the fan moves. A common starting point is about one CFM for each square foot of floor area, with a minimum that many guidelines set at 50 CFM for a small bathroom. A bathroom with a large shower, a tub or high ceilings may need more capacity. Some installers and codes also use air changes per hour, which is the number of times the room's full volume of air is replaced in an hour. Your installer or local code may use either method.

For example, a 6-foot by 8-foot bathroom has 48 square feet of floor area, which would suggest a fan rated at about 50 CFM as a starting point. A larger room or a bathroom with a steam shower should use a higher rating. Always confirm the sizing rule your local building department uses, since requirements vary.

Scroll sideways to see the full table →

Room situationTypical sizing approach
Up to 100 square feetAbout 1 CFM per square foot, with a 50 CFM minimum
Over 100 square feetAdd about 50 CFM for each toilet, shower and tub, and about 100 CFM for a jetted tub
Steam showerFollow the steam unit maker's ventilation instructions
Ceiling above standard heightAccount for extra volume

Local code may set its own minimum. The model code commonly requires 50 CFM intermittent or 20 CFM continuous, so confirm the rule with your building department before you buy.

Place the fan for airflow

Place the fan near the shower or tub, where the steam is generated. In many bathrooms, the best spot is the ceiling above or near the wet area, because warm, moist air rises. A fan or fan-light installed above a tub or shower must be listed for that location, and many manufacturers require it to be on a ground-fault protected circuit. Ask your electrician to confirm the listing before you buy, and check local code with your building department. Avoid placing the fan directly over the toilet if a better location exists, and keep the intake clear of furniture or walls that block airflow.

The fan should also match the room's door and air supply. A closed door with no gap can make it harder for air to reach the fan, so consider a transfer grille or a gap under the door. Ask the installer to check the location against the joists and the ductwork, because a fan placed in the wrong bay can require a long duct run that loses much of the fan's rated performance.

Vent the fan outdoors

The duct must carry moist air to the outside of the house, through a roof cap or a wall vent. Venting into the attic or a soffit cavity is a common mistake that causes condensation, rot and mold. Use rigid or smooth ducting where possible, keep the run short and straight, and insulate the duct where it passes through an unheated space to prevent condensation inside it. Slope the duct slightly so any moisture drains outward rather than pooling.

Check the outdoor vent after installation. A damper that sticks closed or a vent that is blocked by debris will stop the airflow, so confirm that the damper opens freely when the fan runs.

Check noise, controls and features

Noise is the reason many people turn fans off. Look at the sound rating in sones, which is measured by the manufacturer, and compare models with the same CFM. Quieter fans generally cost more, but the difference in daily comfort can be large. Some fans include a humidity sensor that runs the fan automatically, and others include a timer that keeps it running for a set period after the shower ends. Both features help keep the room dry without relying on memory.

Check whether the fan has a light, a heater or a night-light, and whether the controls are where you can reach them. Confirm with your electrician that the switch and circuit match the fan's wiring requirements.

Before you buy

Measure the bathroom, decide where the shower or tub sits, and ask your installer for a fan rating and duct route before you buy. Compare two or three models with the same airflow, check their noise ratings and confirm the venting plan in writing. Be sure to confirm the outdoor vent location with your contractor before the ceiling is closed.